Sulfur Analyzer

The Sindie sulfur analyzer is used to determine the total sulfur in gasoline, diesel fuels, and other petroleum products. The analyzer employs a method based monochromatic excitation wavelength-dispersive X-ray fluorescence (MWDXRF) spectrometry to measure sulfur content. The Sindie MWDXRF analyzer engine configuration is below.

Sindie Family Products

  • Sindie ® 2622
  • Sindie ® 7039 G3
  • Sindie ® 7039 Plus Pb
  • Sindie ® On-The-Go
Sindie 2622 Benchtop Analyzer

sp10

The Sindie ® 2622 benchtop analyzer complies with ASTM D2622, D7039 and ISO 20884 methods, enabling complete flexibility in sulfur analysis. No compromises in detection, performance and reliability — the Sindie ® 2622 analyzer is the ideal sulfur analytic solution from ultra low sulfur diesel and gasoline to heavy fuel oil and crude. One analyzer, three compliance solutions.

SINDIE Autosampler

  • 8 sample cell capacity
  • Increases productivity
  • Utilitizes XOS Accu-Cell cups
  • Methods
  • Benefits
  • Applications
  • Specifications

ASTM D2622, D7039 and ISO 20884

  • LOD: 0.15 ppm at 300 s.
  • Dynamic Range: 0.15 ppm to 10%
  • Fits on any bench: 37 cm (w) x 50 cm (d) x 34 cm (h).
  • User programmable measurement time:30-900 s.
  • Two calibrations cover a variety of products over full dynamic range:
    • 0.4 – 3000 ppm wt
    • 0.3 – 10% wt
  • No conversion gasses, heating elements, quartz tubes or columns.
  • 75 W air-cooled excitation tube.
  • Robust polyamide window for easy cleaning.
  • Total sulfur analysis from ultra low sulfur fuels to crudes.
  • For use in refinery labs, pipeline terminals, additive plants and inspection laboratories.
  • Utilities  : None
  • Sample Cup Volume : 1 ml
  • Ambient Temperature Requirements : 5-40C (40-104F)
  • Dynamic Range : 0.15ppm – 10 % wt.
  • Measurement time : 30-900 s
  • Calibration: 8 calibration curves. Automatic and Manual Calibration functionality
Sindie 7039 G3

sp10

The Sindie® 7039 Benchtop model is specifically designed for fast batch testing from 0.15 – 3000 ppm (wt.) sulfur fuel samples at petroleum pipeline terminals, refineries, and test laboratories. The unit is compact and fits on any lab bench with an easy-to-use and robust design for industrial and laboratory use with minimal maintenance. The Sindie ® analyzer has many advantages over competing technologies. The analyzer has exceptional signal-to-noise using monochromatic excitation of the X-ray source characteristic line. It does not require consumable gases or high-temperature operations improving the analyzer’s robustness and reliability.

Sindie 7039 Benchtop complies with ASTM Standard D-7039. Sindie ® 7039 Benchtop meets or exceeds the performance of other X-ray fluorescence-based ISO and ASTM test methods including ISO 20884, for the measurement of sulfur in refinery fuels.

  • Methods
  • Benefits
  • Applications
  • Specifications

ASTM D7039 and ISO 20884

  • LOD: 0.15 ppm at 300 s.
  • Dynamic Range:
  • Standard: 0.15 ppm to 3000 ppm
  • XR package: 0.15 ppm to 10%
  • Available with 8 cell auto-sampler.
  • Utilizes ACCU-CELL pre-assembled and pre-vented sample cups for enhanced precision,
  • extreme ease-of-use and enhanced productivity.
  • User programmable measurement time: 30-900 s.
  • One calibration curve will run both diesel and gasoline up to 3000 ppm.
  • No conversion gasses, heating elements, quartz tubes or columns.
  • 75 W air-cooled excitation tube.
  • Robust polyamide window for easy cleaning.
  • Total sulfur analysis from ultra low sulfur fuels to crudes.
  • For use in refinery labs, pipeline terminals, additive plants and inspection laboratories.
  • Utilities  : None
  • Sample Cup Volume : 1 ml
  • Ambient Temperature Requirements : 5-40C (40-104F)
  • Dynamic Range : 0.15ppm – 10% wt.
  • Measurement time : 30-900 s
  • Calibration: 8 calibration curves. Automatic and Manual Calibration functionality

 

Sindie 7039 plus Pb

sp10

From ultra low sulfur diesel and gasoline to heavy fuel oil and crude, the Sindie 7039 Plus Pb Analyzer delivers unprecedented precision and accuracy for sulfur detection with the added option for measuring lead. As aviation industry requirements become more stringent, lead detection is critical in such products as aviation gasoline and jet fuel.

XOS offers an ideal analytical solution for the energy industry where  detection, performance, and reliability are essential. Simply plug it in and measure. Results with one touch. Unrivaled precision.

Sindie 7039 Plus Pb Benchtop complies with ASTM Standard D7039. Sindie 7039 Plus Pb Benchtop meets or exceeds the performance of other X-ray fluorescence-based ISO and ASTM test methods including ISO 20884, for the measurement of sulfur in refinery fuels.

 

  • Methods
  • Benefits
  • Applications
  • Specifications

ASTM D7039 and ISO 20884

  • LOD
    • Sulfur : 0.7 ppm at 300s
    • Lead : 0.002 ppm at 300s
  • Dynamic Range:
    • Sulfur : 1 ppm to 5000 ppm
    • Lead : 0.002 g/l to 10.000g/l.
  • User programmable measurement time: 30-900 s.
  • No conversion gasses, heating elements, quartz tubes or columns.
  • 75 W air-cooled excitation tube.
  • Robust polyamide window for easy cleaning.
  • Total sulfur and lead  analysis from ultra low sulfur fuels to aviation gasoline and crudes.
  • For use in refinery labs, pipeline terminals, additive plants testing vans and inspection laboratories.
  • Sample Cup Volume : 10 ml
  • Ambient Temperature Requirements : 5-40C (40-104F)
  • Dynamic Range:
    • Sulfur : 1 ppm to 5000 ppm
    • Lead : 0.002 g/l to 10.000g/l.
  • Measurement time : 30-900 s
  • Calibration: 8 calibration curves. Automatic and Manual Calibration functionality